[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[test-results] eglibc-svn-2641 on embedded MPC8540 test results
- To: test-results@xxxxxxxxxx
- Subject: [test-results] eglibc-svn-2641 on embedded MPC8540 test results
- From: Clemens Koller <clemens.koller@xxxxxxxxxxx>
- Date: Wed, 27 Jun 2007 13:39:33 +0200
Here are some test results from eglibc-latest-svn build on an embedded PowerPC MPC8540 (e500) environment:
$ uname -a
Linux ecam 2.6.21-rc5-g9a5ee4cc #4 Mon Apr 2 21:31:53 CEST 2007 ppc e500 GNU/Linux
$ gcc -v
Using built-in specs.
Target: powerpc-unknown-linux-gnu
Configured with: ../gcc-4.2.0/configure --prefix=/usr --libexecdir=/usr/lib --enable-languages=c,c++,objc --enable-threads=posix --enable-__cxa_atexit --enable-clocale=gnu --enable-shared --disable-nls --with-x=no --with-cpu=8540 --with-tune=8540 --with-float=soft --with-long-double-128 --disable-multilib
Thread model: posix
gcc version 4.2.0 (ckcore)
Using kernel-headers-2.6.22-rc3
../eglibc/configure \
--prefix=/usr \
--libexecdir=/usr/lib \
--with-headers=$PKG/usr/include \
--enable-kernel=2.6.0 \
--enable-add-ons=ports,nptl \
--with-__thread \
--with-tls \
--enable-shared \
--disable-profile \
--without-gd \
--without-cvs \
--without-fp \
--without-selinux \
--with-glibc=$SRC/eglibc \
make check fails two tests:
$ cat work/src/build/math/bug-nextafter.out
nextafterl+ did not overflow
nextafterl- did not overflow
nextafterl+ did not underflow
nextafterl- did not underflow
nextafterl+ failed
nextafterl+ did not underflow
nextafterl- failed
nextafterl- did not underflow
nextafterl- failed
nextafterl- did not underflow
$ cat work/src/build/math/bug-nexttoward.out
nexttowardl+ did not overflow
nexttowardl- did not overflow
nexttowardl+ did not underflow
nexttowardl- did not underflow
nexttowardl+ failed
nexttowardl+ did not underflow
nexttowardl- failed
nexttowardl- did not underflow
nexttowardl- failed
nexttowardl- did not underflow
Comments are welcome!